Goodman 8 kW Electric Heat Kit W/Circuit Breaker
$160.43

HKTSD08X1 is a Goodman 8 kW electric heat kit designed for compatible Goodman air handlers. It operates on 208–240V single-phase power and includes circuit-breaker protection for dependable residential heating.
- Heating capacity: 8 kW
- Heating output at 240V: Approximately 27,300 BTU/h
- Electrical supply: 208–240V, single phase
- Protection: Built-in circuit breaker
- Compatible series: Select Goodman AMST and DFVE air handlers
- Application: Residential electric HVAC systems
HKTSD08X1 Goodman 8 kW Electric Heat Kit
HKTSD08X1 is an 8 kW electric heat kit designed to provide dependable heating when installed in a compatible Goodman air handler. It operates on 208–240V single-phase electrical power and includes built-in circuit-breaker protection.
This accessory is installed inside an approved indoor air handler. Its electric resistance elements warm the air moved by the blower, allowing a compatible residential HVAC system to deliver heated air throughout the property.
Reliable 8 kW Electric Heating
The HKTSD08X1 provides a nominal heating capacity of 8 kW. At 240 volts, this equals approximately 27,300 BTU per hour. Actual output will be lower when the heat kit operates on a 208-volt electrical supply.
The correct heat-kit capacity should be determined through a professional heating-load calculation. Property size, insulation, climate, windows, air leakage, ductwork, outdoor temperature, and heat-pump performance can all affect the amount of electric heating required.
Built-In Circuit-Breaker Protection
This Goodman heat kit includes circuit-breaker protection as part of its electrical configuration. The breaker provides an accessible disconnecting and protective device for the heating assembly when the accessory is installed according to manufacturer instructions.
The included breaker does not replace every electrical protection requirement. A qualified professional must confirm the correct supply circuit, wire size, grounding, external disconnect, electrical-panel capacity, and upstream overcurrent protection.
Compatible Goodman Air Handlers
The HKTSD08X1 is designed for select Goodman AMST and DFVE series air handlers. Compatibility must always be confirmed using the complete air-handler model number and the manufacturer’s current accessory information.
This electric heat kit is not a universal accessory. Matching the Goodman brand, cabinet width, or system tonnage alone does not guarantee that the heater will fit or operate correctly.
The indoor unit’s cabinet configuration, electrical rating, control system, blower capacity, available airflow, and approved heating options must support the selected heat kit.
Electric Heat for Straight-Cool Systems
When installed in a compatible Goodman air handler paired with an air-conditioning condenser, the heat kit can provide the system’s indoor heating. The outdoor condenser supplies cooling during warm weather, while the electric heating elements produce heat when requested by the thermostat.
This configuration may be useful for residential properties without natural-gas service or applications where an electric heating source is preferred. Proper system matching, electrical preparation, and professional installation remain essential.
Auxiliary Heat for Heat Pump Systems
The HKTSD08X1 may also support a compatible Goodman heat-pump system. During cold weather, an air-source heat pump can require additional heating capacity. The electric heat kit may provide auxiliary heat when the system controls determine that supplemental heating is necessary.
The kit may also provide emergency electric heat when supported by the air handler, thermostat, and control configuration. Emergency mode allows the electric elements to operate without depending on the outdoor heat-pump compressor.
Available heating stages and operating modes depend on the complete equipment match, thermostat, control wiring, and installer settings.
208–240V Single-Phase Operation
This model operates on 208–240V single-phase electrical power. Electric resistance heating creates a substantial electrical load, so the property’s electrical panel and available service capacity must be evaluated before installation.
At 208 volts, the published amperage is approximately 41.9 amps. At 240 volts, the published amperage is approximately 47 amps. Final electrical requirements must always be taken from the heat-kit and matched air-handler nameplates.
A qualified installer must determine the required conductor size, circuit configuration, breaker rating, grounding, disconnecting means, and installation method according to current electrical codes.
Correct Airflow Is Essential
Adequate airflow across the electric heating elements is necessary for safe operation. Restricted airflow can create excessive temperature rise, activate safety-limit controls, reduce comfort, and potentially damage the heating assembly or air handler.
The installer should inspect the filter, return-air opening, supply ducts, blower-speed setting, external static pressure, and temperature rise. Correct airflow helps the HKTSD08X1 deliver balanced and reliable heating performance.
Professional Installation Required
Installation should be performed by a licensed HVAC technician or qualified electrician. All power sources must be disconnected before installing, inspecting, or servicing the equipment.
The technician should follow the instructions supplied with the heat kit and air handler, secure the heating assembly, complete the high-voltage and control connections, and inspect the wiring before restoring electrical power.
After installation, every available heating stage should be tested. The technician should verify proper amperage, blower operation, thermostat control, temperature rise, circuit-breaker operation, safety-limit performance, and secure electrical connections.
Key Features of the HKTSD08X1
- 8 kW nominal electric heating capacity
- Approximately 27,300 BTU/h at 240V
- 208–240V single-phase operation
- Built-in circuit-breaker protection
- Designed for select Goodman AMST and DFVE air handlers
- Suitable for approved residential HVAC applications
- Can support compatible straight-cool systems
- May provide auxiliary or emergency heat for heat pumps
- Field-installed air-handler accessory
- Professional installation required
Explore additional electric heat kits from Xpress Supply or review the official Goodman air-handler information before selecting compatible equipment.
Important: Confirm air-handler compatibility, voltage, available electrical capacity, circuit requirements, airflow, control configuration, and applicable codes before ordering or installing the HKTSD08X1.
| Weight | 10 lbs |
|---|---|
| Dimensions | 23 × 12 × 6 in |
| Model # | HKTSD08X1 |
| Heating Type | Electric Heat |
| Application | Residential |
About Goodman
Founded in 1982, Goodman is one of North America’s most recognized HVAC brands. As part of Daikin Industries, Goodman combines global engineering expertise with reliable performance, energy-efficient technology, and strong value for residential heating and cooling applications.Why Choose Goodman?
- Air conditioners, heat pumps, gas furnaces, air handlers, coils, and packaged units
- Energy-efficient SEER2 equipment options
- Durable components designed for dependable operation
- ComfortBridge™, SmartShift®, and other advanced technologies on select models
- Complete residential HVAC system solutions

Air Conditioner Systems (Electric Heat)
Gas Split System
Heat Pump Systems
Mini Split Systems
Package Units
Mobile Home Systems
AC & Heat Pump Condensers
Evaporator Coils
Air Handlers
Electric Heat Kits
Furnace
Condenser Pad
Drain Pans
Fittings & Connections
Flue Pipe
Line Set
Thermostat
PVC Pipe & Fittings
Miscellaneous Supplies
Ducting & Venting
Exhaust Fan
Flex Duct
Return Plenum
Supply Plenum
Registers & Grilles
Filters
Grilles