Supply Plenum R8 16 x 19 3/4 x 48

$218.78

Financing Options

Supply Plenum R8 16 x 19 3/4 x 48 is an insulated galvanized-metal plenum designed to connect compatible indoor HVAC equipment with the supply duct system. Its R8 insulation and 26-gauge construction support dependable air distribution.

  • Measures 16 x 19 3/4 x 48 inches
  • R8 insulated construction
  • 26-gauge galvanized metal
  • Knocked-down design for assembly
  • Silver exterior finish
  • Made in the USA
  • Designed for HVAC supply-air applications
Description

}

Supply Plenum R8 16 x 19 3/4 x 48 is an insulated galvanized-metal air-distribution component designed to connect compatible indoor HVAC equipment with the supply duct system. It receives conditioned air from the equipment and provides a chamber for attaching appropriately sized duct branches.

This supply plenum measures 16 inches by 19 3/4 inches by 48 inches. Its R8 insulation helps limit unwanted heat transfer, while the 26-gauge galvanized-metal construction provides strength for professional residential HVAC installations.

Supply Plenum R8 16 x 19 3/4 x 48 Features

The Supply Plenum R8 16 x 19 3/4 x 48 combines durable metal construction with an enhanced insulation rating. It is supplied in a knocked-down configuration and must be assembled, secured and sealed during installation.

  • 16 x 19 3/4 x 48-inch product size
  • R8 thermal insulation rating
  • 26-gauge metal construction
  • Galvanized for additional material protection
  • Knocked-down assembly design
  • Silver exterior finish
  • Non-flanged configuration
  • Approximate weight of 21.75 pounds
  • Manufactured in the United States

The rectangular configuration provides surfaces for adding compatible supply-air collars and duct takeoffs. The size, number and location of these connections must be determined according to the complete duct-system design.

HVAC Supply-Air Distribution

The Supply Plenum R8 16 x 19 3/4 x 48 installs on the supply side of compatible air handlers, evaporator-coil assemblies or furnaces. Conditioned air enters the plenum before being distributed into the branch ducts serving different rooms or zones.

A properly sized plenum helps distribute airflow without creating unnecessary restrictions. Incorrect dimensions, poorly located takeoffs or excessive openings can affect air velocity, static pressure, sound levels and indoor comfort.

The plenum should be selected as part of the complete HVAC air-distribution design. Equipment capacity, blower performance, available static pressure, duct dimensions and required room airflow must all be considered.

Do not select a supply plenum solely according to HVAC equipment tonnage. Cabinet dimensions and supply openings can vary between manufacturers, models and installation orientations.

Installing the Supply Plenum R8 16 x 19 3/4 x 48

Before installing the Supply Plenum R8 16 x 19 3/4 x 48, confirm the dimensions of the indoor equipment’s supply-air outlet. Verify that the available installation area provides enough space for the 48-inch plenum, duct connections and future equipment service.

Assemble the knocked-down panels carefully and confirm that all corners and seams align properly. The completed plenum should form a stable enclosure without large gaps, loose panels or damaged insulation.

Because this product is not flanged, the installer must use an attachment method suitable for the HVAC equipment and application. A field-fabricated transition may be necessary when the plenum and equipment openings do not match exactly.

Position the plenum squarely with the equipment outlet and support it adequately. The plenum and connected ductwork should not place excessive weight or stress on the air handler, coil cabinet or furnace.

Benefits of R8 Insulation

The R8 insulation incorporated into the Supply Plenum R8 16 x 19 3/4 x 48 helps slow heat transfer between the conditioned air and the surrounding installation space.

This thermal protection is particularly beneficial when the plenum is installed in an attic, garage, mechanical room or another unconditioned location. Limiting heat gain or loss can help preserve the temperature of the air leaving the HVAC equipment.

Insulation can also help control exterior condensation when cold supply air passes through a warm and humid environment. However, the vapor barrier, panel seams, equipment connection and duct penetrations must remain properly sealed.

Although R8 insulation meets many common installation requirements, local energy codes can vary. Verify that the insulation rating is suitable for the building, climate and installation area.

Adding Supply Duct Connections

Plan the size and position of all supply-air takeoffs before cutting openings in the Supply Plenum R8 16 x 19 3/4 x 48. Avoid damaging the internal insulation or cutting too close to panel seams and equipment connections.

Remove sharp edges and loose fragments after creating each opening. Secure the collars mechanically and seal the complete perimeter using HVAC-approved mastic, sealant or tape.

When connecting insulated flexible duct, secure and seal the inner liner first. Restore the insulation and exterior vapor barrier around the connection to reduce air leakage, heat transfer and condensation.

Avoid compressing or sharply bending flexible duct near the plenum. These conditions can increase airflow resistance. Rigid ductwork should also remain correctly aligned and independently supported.

Advantages of the 48-Inch Length

The 48-inch length provides additional surface area for positioning compatible supply takeoffs. This can be useful when several duct branches must connect to the same supply plenum.

Additional length does not automatically mean the plenum is suitable for every system. The installer must still determine the appropriate number, size and location of the duct connections according to calculated airflow requirements.

The longer assembly also requires adequate structural support. Do not allow the full weight of the plenum and connected ductwork to rest on the indoor HVAC equipment.

Sealing the Plenum

All panel joints, seams and penetrations must be sealed after assembly. Conditioned air escaping from the supply plenum can reduce the amount of heating or cooling delivered to occupied rooms.

Use products specifically approved for HVAC duct systems. Ordinary cloth-backed utility tape should not be considered a permanent method for sealing plenum seams or duct connections.

Inspect the insulation and vapor barrier after completing the installation. Repair tears, exposed edges or openings around duct takeoffs using compatible materials.

Product Specifications

  • Product type: Insulated supply-air plenum
  • Size: 16 x 19 3/4 x 48 inches
  • Material: Metal
  • Gauge: 26 GA
  • Galvanized: Yes
  • Insulated: Yes
  • Insulation rating: R8
  • Color: Silver
  • Flanged: No
  • Approximate weight: 21.75 pounds
  • Country of origin: United States

Confirming Equipment Compatibility

Measure the equipment outlet before purchasing the Supply Plenum R8 16 x 19 3/4 x 48. The listed dimensions should match the intended connection or be accommodated with a properly designed transition.

Consider nearby framing, wiring, refrigerant piping, drain lines and service panels. The installation must not obstruct access required for equipment inspection or maintenance.

A qualified HVAC contractor can determine whether the plenum provides sufficient area for the equipment’s required airflow. The contractor should evaluate the complete duct system and verify static pressure after installation.

Professional Installation Recommended

Supply Plenum R8 16 x 19 3/4 x 48 should be assembled and installed by a qualified HVAC professional. Proper sizing, support, sealing and insulation continuity are necessary for dependable performance.

This product includes the supply plenum only. Collars, ductwork, transitions, fasteners, mastic and other installation materials may be sold separately.

Browse additional options in the Xpress Supply Supply Plenum category. For official information regarding stationary air-conditioning equipment and technician requirements, visit the EPA Section 608 refrigeration and air-conditioning resources.

About XSupply
Quality HVAC parts, air filters, replacement components, and installation supplies designed to deliver reliable performance, dependable compatibility, and exceptional value for residential and commercial HVAC systems.