Rheem Select 75,000 BTU 80% AFUE Gas Furnace

$1,286.65

Financing Options

W801T0754A17UHSNAS is a Rheem Select 75,000 BTU gas furnace designed for upflow or horizontal residential installation. It features 80% AFUE, single-stage heating, direct spark ignition and a five-speed constant-torque ECM blower.

  • 75,000 BTU heating input
  • Approximately 60,000 BTU heating output
  • 80% AFUE efficiency
  • Single-stage gas heating
  • Five-speed constant-torque ECM blower
  • Upflow or horizontal configuration
  • 17.5-inch cabinet width
SKU: XPS-FUR-0005 Categories: , Tag:
Description

W801T0754A17UHSNAS Rheem 75,000 BTU Gas Furnace

W801T0754A17UHSNAS is a Rheem Select residential gas furnace designed to deliver dependable heating and flexible airflow. It provides 75,000 BTU per hour of heating input, approximately 60,000 BTU per hour of heating output and 80% AFUE performance. Its single-stage heating system and five-speed constant-torque blower make it suitable for compatible residential split HVAC systems.

This low-profile furnace supports upflow or horizontal installation. It can be paired with an approved evaporator coil and outdoor air conditioner to create a complete gas split system. The furnace, coil and condenser must be correctly sized and matched before installation.

75,000 BTU Heating Input

The W801T0754A17UHSNAS has a rated natural-gas heating input of 75,000 BTU per hour. With its 80% AFUE rating, the furnace supplies approximately 60,000 BTU per hour of usable heating output under standard test conditions.

AFUE represents the percentage of fuel energy converted into useful seasonal heat. An 80% AFUE furnace transfers approximately 80% of the fuel’s energy into the conditioned space, while the remaining portion exits through the venting system.

A professional heating-load calculation should be completed before selecting the furnace. Climate, insulation, windows, air leakage, ceiling height, building construction and duct condition all influence the amount of heat required. Furnace capacity should not be selected using square footage alone.

Single-Stage Heating

The W801T0754A17UHSNAS uses single-stage gas heating. When the thermostat calls for heat, the furnace operates at its available heating capacity until the indoor temperature reaches the selected setting.

This straightforward design provides familiar operation and service requirements. Proper sizing is especially important because an oversized single-stage furnace may cycle too frequently, while an undersized furnace may struggle to maintain comfort during periods of high heating demand.

Five-Speed Constant-Torque Blower

The W801T0754A17UHSNAS includes a five-speed constant-torque ECM blower motor. Multiple airflow settings allow the installer to coordinate heating airflow with the selected evaporator coil and outdoor air conditioner.

This model uses a nominal 4 ton blower drive and provides approximately 1,402 CFM at its published cooling rating point. Actual airflow depends on the selected motor speed, evaporator coil, duct static pressure, filter condition and complete system configuration.

The 4 ton designation refers to the blower’s nominal cooling support. It does not mean that the furnace produces four tons of heat. Gas-heating performance is determined by the 75,000 BTU input and approximately 60,000 BTU output.

Upflow or Horizontal Installation

The W801T0754A17UHSNAS is approved for upflow or horizontal installation. In an upflow application, return air enters through the lower portion of the furnace and heated air exits through the top. In a horizontal application, the furnace operates on its side in an approved orientation.

The furnace must not be installed on its back with the access doors facing upward. Installation position, venting, combustion-air requirements, service access and clearances must follow the manufacturer’s instructions.

This furnace is not approved or recommended for manufactured or mobile homes. It is designed for compatible site-built residential applications. Manufactured housing requires equipment specifically certified for that type of installation.

Direct Spark Ignition and Diagnostics

A direct spark ignition system electronically lights the burners when the thermostat requests heating. This eliminates the need for a continuously burning standing pilot and supports reliable furnace operation.

The integrated seven-segment diagnostic display helps qualified technicians identify operating conditions and faults during installation or service. The blower compartment also includes a safety switch that interrupts operation when its access panel is removed.

Durable Cabinet and Heat Exchanger

The W801T0754A17UHSNAS uses an aluminized-steel heat exchanger engineered to resist corrosion and repeated thermal cycling. Its removable heat-exchanger design supports service access, while hemmed cabinet edges and quarter-turn door fasteners simplify maintenance.

The furnace has a low-profile cabinet approximately 34 inches high and 17.5 inches wide. Xpress Supply lists approximate dimensions of 26 inches deep, 17 inches wide and 34 inches high, with a listed product weight of approximately 125 pounds.

Cabinet dimensions are not the same as required installation clearances. Sufficient space must be provided for airflow, combustion air, venting, filter replacement and future service.

Electrical and Gas Requirements

This furnace operates on a 115-volt, single-phase, 60 Hz electrical supply. The manufacturer lists a minimum circuit ampacity of approximately 9 amps and 15-amp overcurrent protection.

The gas connection is 1/2-inch NPT. The factory fuel configuration must be verified before installation. Conversion to propane requires the correct manufacturer-approved kit, burner adjustments and professional combustion testing.

Gas pressure, electrical wiring and grounding must follow the furnace nameplate, manufacturer instructions and applicable codes. All gas connections must be inspected and tested for leaks before operation.

Venting Requirements

As an 80% AFUE furnace, this model requires code-compliant combustion venting. Vent material, diameter, termination, combustion air and clearances must comply with the National Fuel Gas Code, local regulations and Rheem installation instructions.

This furnace is listed as a standard-NOx model. It may not comply with emissions requirements in certain regulated air districts. Local furnace efficiency and emissions rules should be verified before purchase.

Compatible Cooling Equipment

The W801T0754A17UHSNAS is the gas furnace only. It does not include an outdoor condenser, evaporator coil, thermostat, refrigerant line set, filter cabinet, venting or installation accessories unless those items are specifically included in a package.

For central cooling, the furnace must be paired with a compatible evaporator coil and outdoor air conditioner. Coil width, refrigerant type, blower airflow and certified equipment matching must be confirmed before ordering.

Professional Installation Required

The W801T0754A17UHSNAS must be installed and commissioned by a qualified HVAC professional. Installation includes gas-pressure adjustment, combustion testing, venting, electrical wiring, blower setup, temperature-rise verification and safety-control testing.

Review the official Rheem W801T specification sheet and browse more HVAC equipment from Xpress Supply. Confirm the fuel type, heating load, cabinet width and complete system match with your contractor.

Additional information
Weight125 lbs
Dimensions26 × 17 × 34 in
Model #W801T0754A17UHSNAS
ApplicationResidential
About Rheem

About Rheem

Founded in 1925, Rheem has more than a century of experience developing dependable heating, cooling, and water heating solutions. Rheem HVAC equipment combines proven engineering, energy-efficient performance, and advanced comfort technology for residential and light commercial applications.

Why Choose Rheem?

  • Air conditioners, heat pumps, furnaces, air handlers, coils, and complete HVAC systems
  • High-efficiency options designed to reduce energy consumption
  • Durable components and factory-tested performance
  • EcoNet® smart monitoring compatibility on select systems
  • Solutions for residential and light commercial applications

Rheem Warranty and Registration

Rheem provides manufacturer limited warranties on eligible products. Coverage, registration requirements, and warranty terms vary by product and model. Visit the official Rheem Warranty and Registration portal to register equipment or verify available coverage.