Goodman 3 Ton Upflow Gas Split System – 80% AFUE – 15.2 SEER2

From $3,815.11

Financing Options

The Goodman 3 Ton Upflow Gas Split System combines a single-stage GLXS4BA3610 R-32 air conditioner, CAPTA3626B3 upflow/downflow evaporator coil, and GR9S800603BN 60,000 BTU natural gas furnace. This AHRI-certified combination delivers 15.2 SEER2 cooling performance and 80% AFUE gas heating for professionally sized residential applications.

Condenser
Exterior component responsible for expelling the heat absorbed inside your home
Furnace
A furnace is a heating system that heats your home.
Evaporator
Key heat exchanger in refrigeration and air conditioning systems.
Description

The Goodman 3 Ton Upflow Gas Split System is a complete residential heating and cooling package designed for an upflow installation. It combines the Goodman GLXS4BA3610 outdoor air conditioner, CAPTA3626B3 cased evaporator coil, and GR9S800603BN natural gas furnace.

This matched equipment combination provides approximately 36,000 BTU per hour of nominal cooling capacity and 60,000 BTU per hour of furnace input. It is rated at 15.2 SEER2 and 12.0 EER2 under AHRI reference number 214859843. The furnace provides single-stage natural gas heating with an 80% AFUE rating.

Correct system capacity must be determined through a professional HVAC load calculation. Square footage alone does not account for climate, insulation, windows, construction, occupancy, building orientation, ductwork, air leakage, and other conditions that affect heating and cooling requirements.

Goodman 3 Ton Upflow Gas Split System Overview

The Goodman 3 Ton Upflow Gas Split System uses the GLXS4BA3610 single-stage air conditioner from Goodman’s GLXS4B series. This outdoor unit operates with R-32 refrigerant and includes an energy-efficient compressor, condenser fan motor, factory-installed filter drier, high-pressure switch, and service valves with sweat connections.

The CAPTA3626B3 is a cased A-coil designed for compatible upflow or downflow applications. It features all-aluminum evaporator-coil construction, a factory-installed thermal expansion valve, foil-faced cabinet insulation, and a rust-resistant thermoplastic drain pan. In this package, the coil is intended to be installed above the furnace in an upflow configuration.

Natural gas heating is provided by the GR9S800603BN furnace. This model has a nominal input capacity of 60,000 BTU per hour, single-stage gas heating, an 80% AFUE rating, and a multi-speed ECM blower motor. Its 17.5-inch cabinet width matches the selected evaporator coil for proper equipment alignment.

What’s Included

The Goodman 3 Ton Upflow Gas Split System includes the three primary components required for central air conditioning and natural gas heating:

  • Goodman GLXS4BA3610 air conditioner: Three-ton outdoor condenser with single-stage operation and R-32 refrigerant.
  • Goodman CAPTA3626B3 evaporator coil: Cased upflow/downflow A-coil with all-aluminum construction and a factory-installed TXV.
  • Goodman GR9S800603BN gas furnace: 60,000 BTU input natural gas furnace with single-stage heating, 80% AFUE efficiency, and a multi-speed ECM blower.

A thermostat, refrigerant line set, equipment pad, electrical disconnect, wiring, gas piping, venting materials, condensate components, duct transitions, and installation accessories are not included unless specifically listed or selected separately.

Key Features

  • Approximately 36,000 BTU per hour of nominal cooling capacity
  • 60,000 BTU per hour natural gas furnace input
  • 15.2 SEER2 and 12.0 EER2 certified system performance
  • AHRI reference number 214859843
  • 80% AFUE furnace efficiency
  • Single-stage cooling and single-stage gas heating
  • R-32 refrigerant cooling circuit
  • Multi-speed ECM furnace blower motor
  • All-aluminum cased evaporator coil
  • Factory-installed evaporator-coil TXV
  • Matching 17.5-inch coil and furnace cabinet widths
  • Designed for a professionally installed upflow application

Technical Specifications

GLXS4BA3610 Outdoor Air Conditioner

  • Brand: Goodman
  • Model: GLXS4BA3610
  • Equipment type: Split-system air conditioner
  • Nominal cooling capacity: 3 tons / approximately 36,000 BTU per hour
  • Compressor operation: Single stage
  • Refrigerant: R-32
  • Electrical requirement: 208/230 volts, single phase, 60 Hz
  • Dimensions: Approximately 39.5 inches high × 29 inches wide × 29 inches deep
  • Liquid service-valve connection: 3/8 inch
  • Suction service-valve connection: 7/8 inch

CAPTA3626B3 Evaporator Coil

  • Brand: Goodman
  • Model: CAPTA3626B3
  • Equipment type: Cased A-coil
  • Installation orientations: Upflow or downflow
  • Compatible nominal capacity range: 2 to 3 tons
  • Refrigerant: R-32
  • Metering device: Factory-installed TXV
  • Coil construction: All aluminum
  • Cabinet width: 17.5 inches
  • Cabinet depth: 21 inches
  • Cabinet height: 26 inches
  • Liquid-line connection: 3/8 inch
  • Suction-line connection: 7/8 inch

GR9S800603BN Gas Furnace

  • Brand: Goodman
  • Model: GR9S800603BN
  • Fuel type: Natural gas
  • Input heating capacity: 60,000 BTU per hour
  • Nominal output heating capacity: Approximately 48,000 BTU per hour
  • Furnace efficiency: 80% AFUE
  • Heating operation: Single stage
  • Blower motor: Multi-speed ECM
  • Maximum nominal airflow: 1,200 CFM
  • Supported configuration: Upflow or horizontal
  • Package configuration: Upflow
  • Electrical requirement: 115 volts, single phase, 60 Hz
  • Cabinet width: 17.5 inches
  • Approximate dimensions: 33 3/8 inches high × 17.5 inches wide × 28 inches deep

System Compatibility

The efficiency stated for the Goodman 3 Ton Upflow Gas Split System applies specifically to the GLXS4BA3610, CAPTA3626B3, and GR9S800603BN combination represented by AHRI reference number 214859843. Substituting a condenser, evaporator coil, furnace, metering device, or blower setting can change the system’s efficiency and certified performance.

The CAPTA3626B3 supports compatible upflow and downflow installations, while the GR9S800603BN furnace supports upflow and horizontal positioning. This package is specifically presented as an upflow system, with the evaporator coil installed above the furnace.

A qualified HVAC professional must confirm equipment positioning, furnace and coil alignment, available installation space, supply and return duct connections, required clearances, blower settings, condensate drainage, natural gas service, and venting requirements.

R-32 Refrigerant Information

The cooling components in the Goodman 3 Ton Upflow Gas Split System use R-32 refrigerant. Installation and service require R-32-compatible tools, components, procedures, and safety practices. Refrigerant piping, evacuation, leak testing, charging, and commissioning must be completed by qualified personnel according to Goodman instructions and applicable regulations.

The outdoor air conditioner is factory charged for the manufacturer’s specified standard tubing length. The installer must verify the actual refrigerant line length, required line sizes, installation conditions, and any necessary refrigerant adjustment before commissioning the equipment.

Warranty and Official Documentation

Warranty coverage varies according to the individual component, installation, application, registration status, property type, location, and Goodman’s current warranty terms. Product registration may be required within the manufacturer’s specified period to receive enhanced coverage where permitted.

Review the applicable Goodman warranty information before purchase and complete the Goodman product registration after installation.

Technical information is available in the official Goodman GLXS4B product specifications, Goodman CAPTA coil specifications, and Goodman GR9S80 furnace specifications.

Professional Installation Notice

The Goodman 3 Ton Upflow Gas Split System requires professional installation. A qualified HVAC contractor must verify the cooling and heating load, equipment compatibility, natural gas supply, venting, combustion-air requirements, electrical service, refrigerant piping, condensate drainage, ductwork, airflow, clearances, permits, and local code requirements.

Use the Xpress AC sizing calculator only as an initial planning resource. Final capacity and equipment selection should be confirmed through an appropriate residential load calculation before purchasing or installing the system.

Additional information
ApplicationResidential
Configuration AirflowHorizontal
Cooling Capacity3 Tons
Efficiency15.2 SEER2
Home Size1,200 – 1,800 sq ft
RefrigerantR-32
StageSingle Stage
System TypeGas, Straight Cool
About Goodman

About Goodman

Founded in 1982, Goodman is one of North America’s most recognized HVAC brands. As part of Daikin Industries, Goodman combines global engineering expertise with reliable performance, energy-efficient technology, and strong value for residential heating and cooling applications.

Why Choose Goodman?

  • Air conditioners, heat pumps, gas furnaces, air handlers, coils, and packaged units
  • Energy-efficient SEER2 equipment options
  • Durable components designed for dependable operation
  • ComfortBridge™, SmartShift®, and other advanced technologies on select models
  • Complete residential HVAC system solutions

Goodman Warranty and Registration

Goodman offers manufacturer limited warranties on eligible equipment. Coverage and registration requirements vary by model, application, installation location, and applicable regulations. Visit the official Goodman Product Registration portal to register qualifying equipment.