Goodman 1.5 Ton Upflow Gas Split System – 80% AFUE – 15.2 SEER2

From $3,273.90

Financing Options

The Goodman 1.5 Ton Upflow Gas Split System combines a single-stage GLXS4BA1810 R-32 air conditioner, CAPTA2422B3 upflow/downflow evaporator coil, and GR9S800603BN 60,000 BTU natural gas furnace. This AHRI-certified combination delivers 15.2 SEER2 cooling performance and 80% AFUE gas heating for professionally sized residential applications.

Condenser
Exterior component responsible for expelling the heat absorbed inside your home
Furnace
A furnace is a heating system that heats your home.
GR9S800603BN
1 × Goodman 60,000 BTU 80% AFUE Gas Furnace
$1,053.81
GR9S800603BN
1 × Goodman 80,000 BTU 80% AFUE Gas Furnace
$1,178.84
Evaporator
Key heat exchanger in refrigeration and air conditioning systems.
Description

The Goodman 1.5 Ton Upflow Gas Split System is a complete residential heating and cooling package designed for an upflow installation. It combines the Goodman GLXS4BA1810 outdoor air conditioner, CAPTA2422B3 cased evaporator coil, and GR9S800603BN natural gas furnace.

This matched equipment combination provides approximately 18,000 BTU per hour of nominal cooling capacity and 60,000 BTU per hour of furnace input. It is rated at 15.2 SEER2 and 12.0 EER2 under AHRI reference number 215214569. The gas furnace provides single-stage heating with an 80% AFUE rating.

Correct system capacity must be determined through a professional HVAC load calculation. Property size alone does not account for climate, insulation, windows, construction, occupancy, ductwork, orientation, and other conditions that influence heating and cooling requirements.

Goodman 1.5 Ton Upflow Gas Split System Overview

The Goodman 1.5 Ton Upflow Gas Split System uses the GLXS4BA1810 single-stage air conditioner from Goodman’s GLXS4B series. This outdoor unit operates with R-32 refrigerant and includes an energy-efficient compressor, ECM condenser fan motor, factory-installed filter drier, high-pressure switch, and service valves with sweat connections.

The CAPTA2422B3 is a cased A-coil designed for compatible upflow or downflow applications. It features an all-aluminum evaporator coil, a factory-installed thermal expansion valve, foil-faced cabinet insulation, and a rust-resistant thermoplastic drain pan. For this product package, the coil is installed in an upflow configuration above the furnace.

Natural gas heating is provided by the GR9S800603BN furnace. This model has a nominal input capacity of 60,000 BTU per hour, single-stage gas heating, an 80% AFUE rating, and a multi-speed ECM blower motor. Its 17.5-inch cabinet width matches the width of the selected evaporator coil.

What’s Included

The Goodman 1.5 Ton Upflow Gas Split System includes the three primary components required for central air conditioning and natural gas heating:

  • Goodman GLXS4BA1810 air conditioner: 1.5-ton outdoor condenser with single-stage operation and R-32 refrigerant.
  • Goodman CAPTA2422B3 evaporator coil: Cased upflow/downflow A-coil with all-aluminum construction and a factory-installed TXV.
  • Goodman GR9S800603BN gas furnace: 60,000 BTU input natural gas furnace with single-stage heating, 80% AFUE efficiency, and a multi-speed ECM blower.

A thermostat, refrigerant line set, equipment pad, electrical disconnect, wiring, gas piping, venting materials, condensate components, duct transitions, and installation accessories are not included unless specifically listed or selected separately.

Key Features

  • Approximately 18,000 BTU per hour of nominal cooling capacity
  • 60,000 BTU per hour natural gas furnace input
  • 15.2 SEER2 and 12.0 EER2 certified system performance
  • AHRI reference number 215214569
  • 80% AFUE furnace efficiency
  • Single-stage cooling and gas heating
  • R-32 refrigerant cooling circuit
  • Multi-speed ECM furnace blower motor
  • All-aluminum cased evaporator coil
  • Factory-installed evaporator-coil TXV
  • Matching 17.5-inch coil and furnace cabinet widths
  • Designed for a professionally installed upflow application

Technical Specifications

GLXS4BA1810 Outdoor Air Conditioner

  • Brand: Goodman
  • Model: GLXS4BA1810
  • Equipment type: Split-system air conditioner
  • Nominal cooling capacity: 1.5 tons / approximately 18,000 BTU per hour
  • Compressor operation: Single stage
  • Refrigerant: R-32
  • Electrical requirement: 208/230 volts, single phase, 60 Hz
  • Dimensions: Approximately 27 inches high × 26 inches wide × 26 inches deep
  • Liquid-line connection: 3/8 inch
  • Suction-line connection: 3/4 inch

CAPTA2422B3 Evaporator Coil

  • Brand: Goodman
  • Model: CAPTA2422B3
  • Equipment type: Cased A-coil
  • Installation orientations: Upflow or downflow
  • Compatible nominal capacity range: 1.5 to 2 tons
  • Refrigerant: R-32
  • Metering device: Factory-installed TXV
  • Coil construction: All aluminum
  • Cabinet width: 17.5 inches
  • Cabinet depth: 21 inches
  • Cabinet height: 22 inches
  • Liquid-line connection: 3/8 inch
  • Suction-line connection: 3/4 inch

GR9S800603BN Gas Furnace

  • Brand: Goodman
  • Model: GR9S800603BN
  • Fuel type: Natural gas
  • Input heating capacity: 60,000 BTU per hour
  • Furnace efficiency: 80% AFUE
  • Heating operation: Single stage
  • Blower motor: Multi-speed ECM
  • System configuration: Upflow
  • Electrical requirement: 115 volts, single phase, 60 Hz
  • Cabinet width: 17.5 inches
  • Approximate dimensions: 33 3/8 inches high × 17.5 inches wide × 28 inches deep

System Compatibility

The efficiency stated for the Goodman 1.5 Ton Upflow Gas Split System applies specifically to the GLXS4BA1810, CAPTA2422B3, and GR9S800603BN combination represented by AHRI reference number 215214569. Substituting a condenser, evaporator coil, furnace, metering device, or blower setting can change the system’s efficiency and certified performance.

The CAPTA2422B3 can support compatible upflow or downflow applications, but this package is configured and marketed as an upflow system. A qualified HVAC professional must confirm equipment positioning, furnace and coil alignment, available installation space, supply and return duct connections, required clearances, airflow settings, and condensate drainage.

R-32 Refrigerant Information

The cooling components in the Goodman 1.5 Ton Upflow Gas Split System use R-32 refrigerant. Installation and service require R-32-compatible tools, components, procedures, and safety practices. Refrigerant piping, evacuation, leak testing, charging, and commissioning must be completed by qualified personnel in accordance with Goodman instructions and applicable regulations.

The outdoor air conditioner is factory charged for the manufacturer’s specified standard tubing length. The installer must verify the actual line-set length, line sizes, installation conditions, and any required refrigerant adjustment before commissioning the equipment.

Warranty and Official Documentation

Warranty coverage varies according to the individual component, installation, application, registration status, property type, location, and Goodman’s current warranty terms. Product registration may be required within the manufacturer’s specified period to receive enhanced coverage where permitted.

Review the applicable Goodman warranty information before purchase and complete the Goodman product registration after installation.

Technical information is available in the official Goodman GLXS4B product specifications, Goodman CAPTA coil specifications, and Goodman GR9S80 furnace specifications.

Professional Installation Notice

The Goodman 1.5 Ton Upflow Gas Split System requires professional installation. A qualified HVAC contractor must verify the cooling and heating load, equipment compatibility, gas supply, venting, combustion-air requirements, electrical service, refrigerant piping, condensate drainage, ductwork, airflow, clearances, permits, and local code requirements.

Use the Xpress AC sizing calculator only as an initial planning tool. Final capacity and equipment selection should be confirmed through an appropriate residential load calculation before purchasing or installing the system.

Additional information
StageSingle Stage
System TypeGas, Straight Cool
RefrigerantR-32
Configuration AirflowHorizontal
Home SizeUp to 1,200 sq ft
ApplicationResidential
Cooling Capacity1.5 Tons
Efficiency15.2 SEER2
About Goodman

About Goodman

Founded in 1982, Goodman is one of North America’s most recognized HVAC brands. As part of Daikin Industries, Goodman combines global engineering expertise with reliable performance, energy-efficient technology, and strong value for residential heating and cooling applications.

Why Choose Goodman?

  • Air conditioners, heat pumps, gas furnaces, air handlers, coils, and packaged units
  • Energy-efficient SEER2 equipment options
  • Durable components designed for dependable operation
  • ComfortBridge™, SmartShift®, and other advanced technologies on select models
  • Complete residential HVAC system solutions

Goodman Warranty and Registration

Goodman offers manufacturer limited warranties on eligible equipment. Coverage and registration requirements vary by model, application, installation location, and applicable regulations. Visit the official Goodman Product Registration portal to register qualifying equipment.